溫控器
Product
Product
聯系我們Contact
us

0510-85416868
手機:18912366584
電話:0510-85416868
傳真:0510-85401718
地址:無錫市梁溪區揚名高新技術產業園匯太路58號
-
溫控器
防爆溫控器與電伴熱帶配套使用后,可以控制管線溫度,且可以調整溫度設定值。Applied with heating cable, temperature controller can adjust temperature in response to practical need.
防爆溫控器 Temperature Controller 圖25

側面圖 圖26
底面圖 圖27
圖28
Maximum temperature: 120℃-150℃-200℃
Explosion-proof temperature controller
? FWK120:控溫范圍Temperature control range(0~120℃)
? FWK200:控溫范圍Temperature control range(50~200℃)
connecting phase line to A, neutral line to N
? a和n用導線接到電源接線盒中,與電熱帶相接;
a terminal and n terminal are connected to heating cable
? 溫控器的探頭接到管路上,用鋁膠帶貼在管道上;
attaching the temperature probe to the surface of the pipe with aluminum adhesive tape
? 溫控器旋鈕調到您所需要維持的溫度上。
adjust the button to the number of practical temperature
Open the cover of the kit, screw off the connection terminal; insert the line through each terminal.
? 按接線腔內的接線圖接好電纜,擰緊接線嘴,上緊接線盒蓋。
Connect the lines as the diagram, tighten the terminal, and then tighten the cover with screws.
? 打開溫度調接盒外蓋,將溫度調整到所需控制溫度處,然后擰緊外蓋。
Adjust the temperature according to the practice need.
? 用卡箍將溫控器底座固定在適當位置,并將溫控探頭緊貼在被測試溫度的部位。
Install the temperature controller at the proper position; attach the probe closely to the vessel.
? 將引出線接到電源盒腔內,與腔內電伴熱帶相接,溫控器進線接入電源,檢查無誤后即可送電工作。
Connect the leading-out line with heating cable, connect the temperature controller to the power. Check the connection, and then turn on the power to operate.
? 溫控探頭只能水平或豎直安裝,否則會出現溫度不穩定現象。
Keep the probe vertical or horizontal, or temperature will be unstable.
? 接線盒如有變形,裂痕和損壞,應停止使用,更換新接線盒。
If the kit was deformed, chapped, please change a new one.
1產品結構 Structure

防爆溫控器 Temperature Controller 圖25

側面圖 圖26

底面圖 圖27
2產品型號 Catalog Number

Maximum temperature: 120℃-150℃-200℃
Explosion-proof temperature controller
3主要技術指標 Technical Parameters(表11)
型號 Catalog number |
防爆等級 Explosion-proof level |
工作電壓 Working voltage |
工作電流 Working current |
控溫精度 Temperature control precision |
絕緣電阻 Insulation resistance |
電氣強度 Dielectric strength |
防護等級 Protection level |
FWK120/200 | ExedⅡBT4 | 380V/220V | ≤15A | ±2.5℃ | ≥60MΩ | 2000V/min | IP54 |
? FWK200:控溫范圍Temperature control range(50~200℃)
4單相溫控器安裝方法 Installation
? 相線接A,零線接N;connecting phase line to A, neutral line to N
? a和n用導線接到電源接線盒中,與電熱帶相接;
a terminal and n terminal are connected to heating cable
? 溫控器的探頭接到管路上,用鋁膠帶貼在管道上;
attaching the temperature probe to the surface of the pipe with aluminum adhesive tape
? 溫控器旋鈕調到您所需要維持的溫度上。
adjust the button to the number of practical temperature
5產品使用與維護 Application and Maintenance
? 打開接線盒蓋,擰下接線嘴,將進線和出線電纜穿過各自的接線口,上緊接線盒蓋。Open the cover of the kit, screw off the connection terminal; insert the line through each terminal.
? 按接線腔內的接線圖接好電纜,擰緊接線嘴,上緊接線盒蓋。
Connect the lines as the diagram, tighten the terminal, and then tighten the cover with screws.
? 打開溫度調接盒外蓋,將溫度調整到所需控制溫度處,然后擰緊外蓋。
Adjust the temperature according to the practice need.
? 用卡箍將溫控器底座固定在適當位置,并將溫控探頭緊貼在被測試溫度的部位。
Install the temperature controller at the proper position; attach the probe closely to the vessel.
? 將引出線接到電源盒腔內,與腔內電伴熱帶相接,溫控器進線接入電源,檢查無誤后即可送電工作。
Connect the leading-out line with heating cable, connect the temperature controller to the power. Check the connection, and then turn on the power to operate.
? 溫控探頭只能水平或豎直安裝,否則會出現溫度不穩定現象。
Keep the probe vertical or horizontal, or temperature will be unstable.
? 接線盒如有變形,裂痕和損壞,應停止使用,更換新接線盒。
If the kit was deformed, chapped, please change a new one.